FEATURES:
•All the functionality and solutions of the handheld ElectriCalc Pro calculator and optimized for the iPhone/iPod Touch user
•Built-in help – just press and hold the desired key for full, clear definitions, explanations and examples of keystrokes
•A complete User’s Guide is available free at (go to ElectriCalc Pro support link below)
•Swipe left to right to edit an entry (backspace)
ElectriCalc Pro Solutions:
•Wire Sizes
•Voltage Drop
•Conduit Sizing
•Motor Full-Load Amps
•Fuse and Breaker Sizes
•NEC® Table Number displayed when performing Wire Size calculations
•Service and Equipment Grounding Conductor Sizes
•Enter BTU to find Kilowatts per Hour
•Enter Kilowatts per Hour to find BTU
•Parallel Resistance
•Ohm’s Law Calculations – enter any two values to solve for the third
•Circular MILS wire sizes
Description of ElectriCalc Pro Calculations:
•Work directly in and convert between Amps, Watts, Volts, Volt-Amps, kVA, kW, PF% and EFF% and DC Resistance
•Calculate wire sizes per NEC® 310-16 and 310-17; Copper or aluminum, 3Ø/1Ø, 60°C, 75°C, 90°C insulation ratings and 100% or 125% of ampacity. Can also adjust wire sizes for ambient temperatures other than 30◦ C and for more than three wires in a raceway
•Integrated voltage drop solutions. Find minimum VD wire size, maximum Length for any given wire size, drop percentage, actual number and percentage of Volts dropped
•Conduit sizing for 12 types of conduit. Per 2005 and 2008 NEC® Table C1-C12, find sizing of all common conduits for any combination for #THW, #XHHW and # THHN wires. Plus, gives fill percentages, cross-sectional areas, remaining areas and more
•Find Motor Full-Load Amps per current NEC®. Works in 1Ø and 3Ø with the new expanded tables for 3Ø induction (to 500 hp) synchronous (to 200 hp) and DC motors per NEC® 430-247, 430- 248 and 430-250.
•Calculates Fuse and Breaker Sizes. Solves fuse and breaker sizes per NEC® 430-52
•Parallel and derated wire sizing
•Parallel Resistance
•NEC Table number displays when performing Wire Size calculations
•Sizes overload protection per NEC® 430-32
•Automatically finds NEMA starter sizes.
•Calculates service and equipment grounding conductor sizes per NEC® 250-122 and 250-66; plus works directly in electrical terms.
•Enter BTU to find Kilowatts per Hour
•Enter Kilowatts per Hour to find BTU
•Ohm’s Law Calculations – enter any two values to solve for the third.
•Enter, solve or convert to Circular MILS wire sizes
TRADEMARKS:
ElectriCalc® is a registered trademark of Calculated Industries, Inc.
Requirements
Your mobile device must have at least 2.03 MB of space to download and install ElectriCalc Pro -- Advanced NEC Code Calculator for Electricians, Electrical Contractors, Inspectors, Plant Engineers and other Building Professionals doing Electrical Math app. ElectriCalc Pro -- Advanced NEC Code Calculator for Electricians, Electrical Contractors, Inspectors, Plant Engineers and other Building Professionals doing Electrical Math was updated to a new version. Purchase this version for $24.99